Converters  AC
AC  Frequency converters
Frequency converters  
BLAST-AT frequency converter
 The BLAST-AT converters are utilized to control many processes and require various control capabilities per the application.
The BLAST-AT converters are utilized to control many processes and require various control capabilities per the application.
Use of  BLAST-AT
This drive was designed to fulfill many applications including the following.
- pumps - centrifugal, positive displacement
- fans - forced and induced draft, centrifugal, axial evaporators
- mixers, agitators, conveyors, winders, centrifuges, extruders, compressors
- machinery for paper, steel and textile industries
- ifts, elevators, cranes and hoists
Features
- Auto Tuning -  tunes the BLAST-AT to the motor specifications and the load
- Speed Profile - controls the minimum/maximum speed profile for requirements
- PID control - controls process with and internal PID loop controller
- Energy Saver - saves energy at lower speeds of operation
- Overload setting - protection designed to protect the motor
- Flying  Re-Start - function used to catch s spinning motor
- Fast  STOP- fast deceleration of the motot fast stop ramp rate
- Auto ON/OFF  via the input control signal, the drive can be START/STOP
- Auto ON/OFF  pomocí vstupního řídícího signálu, pohon může provést START/STOP
- Auto Restart
- JOG function
- minimum/maximum speed setting
Control modes
- V/Hz mode
- Sensorless vector mode
- Vector control mode
|   Pattern lines | 
| three phase supply tension 380V, 415V, 440V, 460V, 480V ± 10% | 
|  | variable moment (cl1) | constant moment (cl2) | 
| Typ | Output current | Power 400V AC | Power 460V AC | DC | Output current | Power 400V AC | Power 460V AC | DC | 
|  | [A] | [kW] | [HP] | [IDC] | [A] | [kW] | [HP] | [IDC] | 
| BLAT258F | 400 | 200 | 300 | 438 | 310 | 160 | 250 | 367 | 
| BLAT292F | 420 | 250 | 350 | 470 | 370 | 200 | 300 | 438 | 
| BLAT340F | 510 | 290 | 400 | 568 | 420 | 250 | 350 | 461 | 
| BLAT420F | 610 | 355 | 500 | 662 | 480 | 280 | 400 | 532 | 
| BLAT520F | 749 | 430 | 600 | 804 | 544 | 315 | 450 | 564 | 
| BLAT580F | 844 | 500 | 700 | 875 | 600 | 355 | 500 | 615 | 
| BLAT670F | 967 | 560 | 800 | 1027 | 781 | 460 | 600 | 994 | 
| BLAT780F | 1135 | 650 | 900 | 1325 | 893 | 525 | 700 | 1264 | 
| three phase supply tension 525V, 550V, 575V, 600V, 660V, 690V ± 10% | 
| BLAT260K | 220 | 200 | 200 | 275,8 | 180 | 160 | 150 | 226 | 
| BLAT320K | 270 | 250 | 250 | 340 | 210 | 200 | 200 | 263 | 
| BLAT390K | 330 | 315 | 300 | 415 | 260 | 250 | 250 | 327 | 
| BLAT480K | 400 | 355 | 400 | 504 | 320 | 315 | 300 | 403 | 
| BLAT520K | 440 | 400 | 450 | 554 | 350 | 355 | 350 | 441 | 
| BLAT640K | 540 | 500 | 500 | 683 | 420 | 400 | 450 | 529 | 
| BLAT780K | 660 | 630 | 600 | 836 | 520 | 500 | 500 | 658 | 
| BLAT960K | 800 | 800 | 800 | 1014 | 620 | 630 | 600 | 785 | 
- Variable torque (VT/cl.1) - 110% for 1 minute, each 10 minutes
- Constant torque (CT/cl.2) - 150% for 1 minute, each 10 minutes
- output calculated for quadrupolar motor
- maximum input current equals to 90% of the output current
- over-current protection of the motor and DC-BUS in place
- BLATxxxY(DC BUS connection) has the same current and output as BLATxxxF
- BLATxxxK (DC BUS connection) has the same current and output as BLATxxxJ
Version G for supply voltage = 500V to order